{"id":104,"date":"2025-10-04T13:43:57","date_gmt":"2025-10-04T13:43:57","guid":{"rendered":"https:\/\/sigmacertteknik.com\/?page_id=104"},"modified":"2025-10-08T11:01:55","modified_gmt":"2025-10-08T11:01:55","slug":"basincli-kaplar","status":"publish","type":"page","link":"https:\/\/sigmacertteknik.com\/?page_id=104","title":{"rendered":"Bas\u0131n\u00e7l\u0131 Kaplar"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"104\" class=\"elementor elementor-104\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0753525 e-flex e-con-boxed e-con e-parent\" data-id=\"0753525\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6f2a391 elementor-widget elementor-widget-text-editor\" data-id=\"6f2a391\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #cf2929;\"><strong>Bas\u0131n\u00e7l\u0131 Kaplar<\/strong><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7467d14 e-flex e-con-boxed e-con e-parent\" data-id=\"7467d14\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fba295d elementor-widget elementor-widget-text-editor\" data-id=\"fba295d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f Gaz Tanklar\u0131 LPG (Yer Alt\u0131 Yer \u00dcst\u00fc) Periyodik Kontrol<\/strong><\/summary>\n\n<p>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f Gaz Tanklar\u0131, \u00e7e\u015fitli sanayi tesisleri, end\u00fcstriyel i\u015fletmeler, konutlar, ula\u015f\u0131m, petrokimya, tar\u0131m ve hayvanc\u0131l\u0131k gibi \u00e7ok \u00e7e\u015fitli sekt\u00f6rlerde kullan\u0131lmaktad\u0131r. Bu gibi alanlarda enerji ihtiyac\u0131n\u0131 kar\u015f\u0131lamak \u00fczere, 0.5 ile 180 m3 aras\u0131nda de\u011fi\u015fen kapasiteli tanklar kullan\u0131lmaktad\u0131r. Bu tanklar, y\u00fcksek kaliteli ve sertifikal\u0131 \u00e7eliklerden \u00f6zel y\u00f6ntemlerle \u00fcretilen bas\u0131n\u00e7l\u0131 kaplard\u0131r.<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f gaz tanklar\u0131, faaliyette bulundu\u011fu s\u00fcre i\u00e7erisinde \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi, TS EN 12817 ve TS EN 12819 standartlar\u0131 gere\u011fi, azami 10 y\u0131lda bir (1) defa periyodik kontrol ve muayene yap\u0131lmas\u0131 zorunludur.<br \/>Ayr\u0131ca bu tanklar\u0131n 10 y\u0131ll\u0131k s\u00fcre i\u00e7erisinde olabilecek \u00e7al\u0131\u015fma \u015feklinde de\u011fi\u015fiklikler, yer de\u011fi\u015ftirme, kazalar, do\u011fal olaylar veya ekipman\u0131n uzun s\u00fcre kullan\u0131lmamas\u0131 vb. g\u00fcvenli\u011fin bozulmas\u0131na neden olabilecek durumlardan sonra; sa\u011fl\u0131k ve g\u00fcvenlik ko\u015fullar\u0131n\u0131n korunmas\u0131 amac\u0131yla Azami Ge\u00e7erlilik S\u00fcresi sona ermeden periyodik kontrol ve muayenesi yeniden yap\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Ta\u015f\u0131nabilir Gaz T\u00fcpleri Periyodik Kontrol<\/strong><\/summary>\n\n<p>Ta\u015f\u0131nabilir Gaz T\u00fcpleri<br \/>Bilindi\u011fi \u00fczere \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi ta\u015f\u0131nabilir bas\u0131n\u00e7l\u0131 kaplar\u0131n periyodik yap\u0131lmas\u0131n\u0131 istemektedir. Ta\u015f\u0131nabilir bas\u0131n\u00e7l\u0131 kaplarda genel olarak oksijen, kar\u0131\u015f\u0131m gazlar\u0131, medikal oksijen, CO2 gaz\u0131 vs. depolanmaktad\u0131r. S\u00f6z konusu gazlar\u0131n periyodik kontrol\u00fc i\u00e7in Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131 ve \u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131n\u0131n \u00c7\u0131kard\u0131\u011f\u0131 y\u00f6netmelik ayr\u0131ca T\u00fcrk Standartlar\u0131 enstit\u00fcs\u00fcn\u00fcn standartlar\u0131 bulunmaktad\u0131r bu kadar fazla y\u00f6netmelik ve standard\u0131n hangisinin uygulanaca\u011f\u0131 \u00e7eli\u015fkili durumlarda nas\u0131l karar verilece\u011fi kafalarda soru i\u015faretlerine neden olmaktad\u0131r. \u00d6ncelikle ta\u015f\u0131nabilir gaz t\u00fcpleri ile ilgili y\u00f6netmelik ve standartlara bakacak olursak;<br \/>\u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131ndan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Ta\u015f\u0131nabilir Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Basit Bas\u0131n\u00e7l\u0131 Kaplar Y\u00f6netmeli\u011fi<br \/>T\u00fcrk Standartlar\u0131 Enstit\u00fcs\u00fcnden TS EN 1802,TS EN 1803, TS EN 1968, TS EN 14876 ve TS EN ISO 16148 standartlar\u0131<br \/>Yukar\u0131da belirtilen \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi Ek-III 2.1.2. maddesine g\u00f6re bilim sanayi ve teknoloji bakanl\u0131\u011f\u0131n\u0131n \u00e7\u0131kard\u0131\u011f\u0131 y\u00f6netmeliklerde belirtilen hususlardan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011finde belirtilen h\u00fck\u00fcmlere ayk\u0131r\u0131 olmayanlar sakl\u0131 kalmak kayd\u0131yla ilgili standartlarda belirtilen kriterlere g\u00f6re yap\u0131l\u0131r. Yani \u00f6ncelik s\u0131ras\u0131 yap\u0131lacak olursa;<br \/>\u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131ndan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi uygulanacak<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi, Ta\u015f\u0131nabilir Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi, Basit Bas\u0131n\u00e7l\u0131 Kaplar Y\u00f6netmeli\u011fi uygulanacak<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan T\u00fcrk Standartlar\u0131 Enstit\u00fcs\u00fcnden TS EN 1802,TS EN 1803, TS EN 1968, TS EN 14876 ve TS EN ISO 16148 standartlar\u0131 uygulanacakt\u0131r.<br \/>Periyodik Muayene S\u00fcresi<br \/>Periyodik Muayenenin s\u00fcresi hususu ise \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi ve standartlarda yer almaktad\u0131r y\u00f6netmelik s\u00fcre konusunda \u00f6nceli\u011fi standarda vermi\u015ftir ve standart da s\u00fcre bulunmamas\u0131 halinde genel s\u00fcre olarak ta\u015f\u0131nabilir gaz t\u00fcpleri i\u00e7in 3 y\u0131ll\u0131k bir periyodik kontrol s\u00fcresi belirlemi\u015ftir.<br \/>Standartta belirtilen s\u00fcreler kabaca \u015funlard\u0131r;<br \/>S\u0131k\u0131\u015ft\u0131r\u0131lm\u0131\u015f gazalar i\u00e7in 5-10 y\u0131l<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f gazlar i\u00e7in 10 y\u0131l<br \/>A\u015f\u0131nd\u0131r\u0131c\u0131- Toksik, \u00c7ok Toksik Gazlar i\u00e7in 3-5 y\u0131l<br \/>Gaz kar\u0131\u015f\u0131mlar\u0131 i\u00e7in 3,5,10 y\u0131ld\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Ta\u015f\u0131nabilir Asetilen T\u00fcpleri Periyodik Kontrol<\/strong><\/summary>\n\n<p>Bilindi\u011fi \u00fczere \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi ta\u015f\u0131nabilir bas\u0131n\u00e7l\u0131 kaplar\u0131n periyodik yap\u0131lmas\u0131n\u0131 istemektedir. Ta\u015f\u0131nabilir bas\u0131n\u00e7l\u0131 kaplarda genel olarak oksijen, kar\u0131\u015f\u0131m gazlar\u0131, medikal oksijen, CO2 gaz\u0131 vs. depolanmaktad\u0131r. S\u00f6z konusu gazlar\u0131n periyodik kontrol\u00fc i\u00e7in Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131 ve \u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131n\u0131n \u00c7\u0131kard\u0131\u011f\u0131 y\u00f6netmelik ayr\u0131ca T\u00fcrk Standartlar\u0131 enstit\u00fcs\u00fcn\u00fcn standartlar\u0131 bulunmaktad\u0131r bu kadar fazla y\u00f6netmelik ve standard\u0131n hangisinin uygulanaca\u011f\u0131 \u00e7eli\u015fkili durumlarda nas\u0131l karar verilece\u011fi kafalarda soru i\u015faretlerine neden olmaktad\u0131r. \u00d6ncelikle ta\u015f\u0131nabilir gaz t\u00fcpleri ile ilgili y\u00f6netmelik ve standartlara bakacak olursak;<br \/>\u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131ndan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Ta\u015f\u0131nabilir Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Basit Bas\u0131n\u00e7l\u0131 Kaplar Y\u00f6netmeli\u011fi<br \/>T\u00fcrk Standartlar\u0131 Enstit\u00fcs\u00fcnden TS EN 1802,TS EN 1803, TS EN 1968, TS EN 14876 ve TS EN ISO 16148 standartlar\u0131<br \/>Yukar\u0131da belirtilen \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi Ek-III 2.1.2. maddesine g\u00f6re bilim sanayi ve teknoloji bakanl\u0131\u011f\u0131n\u0131n \u00e7\u0131kard\u0131\u011f\u0131 y\u00f6netmeliklerde belirtilen hususlardan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011finde belirtilen h\u00fck\u00fcmlere ayk\u0131r\u0131 olmayanlar sakl\u0131 kalmak kayd\u0131yla ilgili standartlarda belirtilen kriterlere g\u00f6re yap\u0131l\u0131r. Yani \u00f6ncelik s\u0131ras\u0131 yap\u0131lacak olursa;<br \/>\u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131ndan \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k Ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi uygulanacak<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi, Ta\u015f\u0131nabilir Bas\u0131n\u00e7l\u0131 Ekipmanlar Y\u00f6netmeli\u011fi, Basit Bas\u0131n\u00e7l\u0131 Kaplar Y\u00f6netmeli\u011fi uygulanacak<br \/>Bilim, Sanayi ve Teknoloji Bakanl\u0131\u011f\u0131ndan T\u00fcrk Standartlar\u0131 Enstit\u00fcs\u00fcnden TS EN 1802,TS EN 1803, TS EN 1968, TS EN 14876 ve TS EN ISO 16148 standartlar\u0131 uygulanacakt\u0131r.<br \/>Periyodik Muayene S\u00fcresi<br \/>Periyodik Muayenenin s\u00fcresi hususu ise \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi ve standartlarda yer almaktad\u0131r y\u00f6netmelik s\u00fcre konusunda \u00f6nceli\u011fi standarda vermi\u015ftir ve standart da s\u00fcre bulunmamas\u0131 halinde genel s\u00fcre olarak ta\u015f\u0131nabilir gaz t\u00fcpleri i\u00e7in 3 y\u0131ll\u0131k bir periyodik kontrol s\u00fcresi belirlemi\u015ftir.<br \/>Standartta belirtilen s\u00fcreler kabaca \u015funlard\u0131r;<br \/>S\u0131k\u0131\u015ft\u0131r\u0131lm\u0131\u015f gazalar i\u00e7in 5-10 y\u0131l<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f gazlar i\u00e7in 10 y\u0131l<br \/>A\u015f\u0131nd\u0131r\u0131c\u0131- Toksik, \u00c7ok Toksik Gazlar i\u00e7in 3-5 y\u0131l<br \/>Gaz kar\u0131\u015f\u0131mlar\u0131 i\u00e7in 3,5,10 y\u0131ld\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Manifoldlu T\u00fcp Demetleri Periyodik Kontrol<\/strong><\/summary>\n\n<p>Periyodik muayenesi yap\u0131lan bas\u0131n\u00e7l\u0131 gaz t\u00fcpleri ve manifoldlu t\u00fcp demetlerinin \u00fczerine A tipi muayene kurulu\u015fu taraf\u0131ndan; \u00f6rne\u011fi Ek-3\u2019de yer alan, periyodik muayene tarihi, A tipi muayene kurulu\u015funun logo veya markas\u0131 ve yapm\u0131\u015f oldu\u011fu periyodik muayenenin s\u0131ra numaras\u0131 ve gelecek periyodik muayene tarihi bilgileri t\u00fcp\u00fcn omuz b\u00f6lgesine so\u011fuk damgalama olarak ili\u015ftirilir<br \/>Bas\u0131n\u00e7l\u0131 gaz t\u00fcpleri ve manifoldlu t\u00fcp demetlerinin periyodik muayenesinin yap\u0131laca\u011f\u0131na ili\u015fkin dolum tesisleri ile A tipi muayene kurulu\u015flar\u0131 aras\u0131nda s\u00fcresi bir y\u0131ldan az olmayacak \u015fekilde bir s\u00f6zle\u015fme imzalan\u0131r.<br \/>Bas\u0131n\u00e7l\u0131 gaz t\u00fcplerinin ve\/veya manifoldlu t\u00fcp demetlerinin periyodik muayenesi A tipi muayene kurulu\u015fu taraf\u0131ndan, periyodik muayene i\u00e7in alt yap\u0131s\u0131 uygun dolum tesislerinde veya A tipi muayene kurulu\u015fu taraf\u0131ndan kendi tesislerinde yap\u0131l\u0131r. 1\/7\/2015 tarihinden itibaren 1976 ve daha eski imal tarihli ve 1\/7\/2016 tarihinden itibaren 1980 ve daha eski imal tarihli bas\u0131n\u00e7l\u0131 gaz t\u00fcpleri ve manifoldlu t\u00fcp demetleri periyodik muayeneye tabi tutulmaz.<br \/>Sigmacert Global uzman ekip ve ekipmanlar\u0131 ile ger\u00e7ekle\u015ftirece\u011fi Manifoldlu t\u00fcp demetleri kontrolleri sonucu tespit edilen eksiklikleri uygunsuzluklar\u0131 veya tehlikeli durumlar\u0131 rapor halinde sizlere sunarak olas\u0131 bir tehlikeli olay\u0131n engellenmesi ve yasal gerekliliklerinizi sa\u011flaman\u0131z ad\u0131na sizlere yard\u0131mc\u0131 olur.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Tehlikeli S\u0131v\u0131lar\u0131n Bulundu\u011fu Tank ve Depolar Periyodik Kontrol<\/strong><\/summary>\n\n<p>End\u00fcstriyel alanlarda depolama tanklar\u0131 haznesi tonlarca a\u011f\u0131rl\u0131\u011f\u0131ndaki malzemeyi alarak muhafaza etmektedir. Genellikle petrol end\u00fcstrisinde kullan\u0131lan depolama tanklar\u0131 g\u0131da end\u00fcstrisinde de kullan\u0131l\u0131r.<br \/>\u00d6zellikle tehlikeli maddelerin depolanmas\u0131nda kullan\u0131lan depolama tanklar\u0131nda diskler bulunmaktad\u0131r. Bu riskler nedeniyle olu\u015fabilecek kazalar nedeniyle can kayb\u0131 ve \u00e7evre kirlili\u011fi ya\u015fanabilir. O o akredite olmu\u015f kurulu\u015flara depolama tanklar\u0131 kontrollerinizi yapt\u0131r\u0131nz. Depolama tanklar\u0131 periyodik kontrolleri ilgili standart\u0131n \u00f6ng\u00f6r\u00fclen s\u00fcreler sakl\u0131 kalmak ko\u015fulu ile tehlikeli s\u0131v\u0131lar\u0131n bulundu\u011fu tank ve depolar\u0131n kontrol s\u00fcresi on y\u0131ld\u0131r i\u015f ekipmanlar\u0131 kullan\u0131m\u0131nda sa\u011fl\u0131k ve g\u00fcvenlik Y\u00f6netmeli\u011fine tabi olan depolama tanklar\u0131 kontrolleri API 620 . API 650 , API 653 API 2610 standartlarda belirtilen kriterlere uygun olarak yap\u0131l\u0131r. Denetle muayene uzman ekip ve ekipmanlar\u0131 ile ger\u00e7ekle\u015ftirdi\u011fi depolama tank\u0131 kontrolleri sonucu tespit edilen eksiklikleri, uygunsuzluklar\u0131 veya tehlikeli durumlar\u0131 rapor halinde sizlere sunarak olas\u0131 bir tehlikeli olay\u0131n engellenmesi ve yasal gerekdiklerinizi sa\u011flaman\u0131z ad\u0131na size yard\u0131mc\u0131 olur.<br \/>\u0130\u015f ekipmanlar\u0131 kullan\u0131m\u0131nda sa\u011fl\u0131k ve g\u00fcvenlik \u015fart Y\u00f6netmeli\u011fi*<br \/>Bu\u00a0y\u00f6netmei\u011fin\u00a0amac\u0131 i\u015f yerinde i\u015f ekipmanlar\u0131n\u0131n kullan\u0131m\u0131 ile ilgili sa\u011fl\u0131k ve g\u00fcvenlik y\u00f6n\u00fcnden uygulamas\u0131 gerekli asgari \u015fartlar\u0131 belirlemektir. 20\/6\/2012 tarihli ve 6331 say\u0131l\u0131 i\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi kanunu kapsam\u0131na giren t\u00fcm i\u015fyerlerini kapsar.<br \/>6331 say\u0131l\u0131 i\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi kanununun 30 ve 31. maddeleri ile 9\/1\/1985 tarihli ve 3146 say\u0131l\u0131 \u00e7al\u0131\u015fma ve Sosyal g\u00fcvenlik Bakanl\u0131\u011f\u0131n\u0131n te\u015fkilat ve g\u00f6revleri hakk\u0131nda kanunun iki ve 13. maddelerine dayan\u0131larak ve 3\/10\/2009 tarihli ve 2009\/104\/EC Say\u0131l\u0131 Avrupa birli\u011fi direktifine paralel olarak haz\u0131rlanm\u0131\u015ft\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Kriyojenik Tanklar Periyodik Kontrol<\/strong><\/summary>\n\n<p>Kriyojenik tanklar i\u00e7erisinde s\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f gaz, oksijen depolamak ve ta\u015f\u0131mak ama\u00e7l\u0131 kullan\u0131l\u0131r. Kriyojenik tanklar -196 derece ve daha alt\u0131 d\u00fc\u015f\u00fck so\u011fuklarda \u00e7al\u0131\u015fabilir ve bar\u0131nd\u0131rabilirler. Bu tanklar i\u00e7 i\u00e7e ge\u00e7irilmi\u015f iki adet tanktan olu\u015fmaktad\u0131r. Kriyojenik tanklar asla paslanmayan \u00e7elik malzemeden \u00fcretilmi\u015ftir.<br \/>Kriyojenik Depolama Tank \u00c7e\u015fitleri<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f azot tanklar\u0131<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f oksijen tanklar\u0131<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f argon tanklar\u0131<br \/>Karbondioksit tanklar\u0131<br \/>S\u0131v\u0131la\u015ft\u0131r\u0131lm\u0131\u015f do\u011fal gaz tanklar\u0131<br \/>\u0130yi malzemelerden \u00fcretilen Kriyojenik tank kontrolleri mutlaka yap\u0131lmal\u0131d\u0131r. \u0130stenmeyen kazalar\u0131n \u00f6n\u00fcne ge\u00e7mek i\u00e7in periyodik kontrollerinizi mutlaka yapt\u0131rmal\u0131s\u0131n\u0131z. Zorunlu olan kontrolleri \u0130\u015f ekipmanlar\u0131 kullan\u0131m\u0131nda sa\u011fl\u0131k ve g\u00fcvenlik \u015fartlar\u0131 y\u00f6netmeli\u011fine g\u00f6re yap\u0131lmal\u0131d\u0131r.<br \/>Sigmacert Global uzman m\u00fchendisleri ile ger\u00e7ekle\u015ftirdi\u011fi kontroller sonucunda firman\u0131z i\u00e7in uygunluk rapor haz\u0131rlamaktad\u0131r. Denetle m\u00fchendisleri ile ger\u00e7ekle\u015ftirdi\u011fi periyodik kontrollerin s\u00fcresi 1 y\u0131ld\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Kullan\u0131mdaki LPG T\u00fcpleri Periyodik Kontrol<\/strong><\/summary>\n\n<p>LPG t\u00fcp\u00fc i\u00e7erisinde LPG Gaz\u0131 bar\u0131nd\u0131ran gerekti\u011finde kullan\u0131lan tehlikeli bir gazd\u0131r ortalama 4-5 mm kal\u0131n sactan \u00fcretilen LPG t\u00fcpleri d\u0131\u015f y\u00fczeyi d\u0131\u015f etkenlerden korunmas\u0131 i\u00e7in epoksi denilen malzeme ile kaplanm\u0131\u015ft\u0131r. \u00c7ok tehlikeli olun LPG t\u00fcpleri g\u00fcvenlik ama\u00e7l\u0131 olarak korunakl\u0131 ortamlarda saklan\u0131r. \u0130\u015fletmelerde Ocak, p\u00fcrm\u00fcz ve mangal gibi alanlarda kullan\u0131l\u0131r.<br \/>\u00c7ok tehlikeli onun HPG t\u00fcpleri mutlaka onaylan\u0131r kurucular taraf\u0131ndan kontrolleri yap\u0131lmal\u0131d\u0131r. T\u00fcplerin y\u0131ll\u0131k olarak periyodik kontrolleri yap\u0131lmal\u0131d\u0131r.<br \/>Sigmacert Global uzman ekip ve \u00e7\u0131kma anlar\u0131 ile ger\u00e7ekle\u015ftirece\u011fi kullan\u0131mdaki LPG t\u00fcpleri kontrolleri sonucu tespit edilen eksiklikleri uygunsuzluklar\u0131 ve tehlikeli durumlar\u0131 rapor halinde sizlere sunarak olas\u0131 bir tehlike olay\u0131n engellenmesi ve yasal gerekliliklerimizi sa\u011flaman\u0131z ad\u0131na sizlere yard\u0131mc\u0131 olur.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Otoklav Periyodik Kontrol<\/strong><\/summary>\n\n<p>Otoklav Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS EN 13060 K\u00fc\u00e7\u00fck Buhar Sterilizat\u00f6rleri<br \/>TS EN 14222 Paslanmaz \u00c7elik G\u00f6vdeli Kazanlar<br \/>TS EN 285 Sterilizasyon-Buhar Otoklavlar\u0131<br \/>Otoklav Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/>Genel Kontroller: Otoklavdan sorumlu personelin e\u011fitim belgesi varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131 ve fonksiyonlara ili\u015fkin i\u015faretlemeler kontrol edilir.<br \/>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri: Ortam uygunlu\u011fu, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri kontrol edilir.<br \/>Otoklav Kontrolleri: Otoklav yerle\u015fimi, muhafazalar ve yal\u0131t\u0131m durumu, bas\u0131n\u00e7 ve vakum kayna\u011f\u0131, deformasyon ve korozyon durumu, kaynak diki\u015flerinin uygunlu\u011fu, h\u00fccre ve ceket durumu kontrol edilir.<br \/>Fonksiyon Kontrolleri: Ya\u011f\/Su besleme ve tahliyesi, doldurma ve bo\u015faltma vanalar\u0131 ve ba\u011flant\u0131lar\u0131, kapak, \u00f6l\u00e7\u00fc aletleri, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131, kontrol cihazlar\u0131, emniyet ventili kontrol edilir.<br \/>Testler:<br \/>\u00d6n haz\u0131rl\u0131klar: Otoklav, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Otoklava, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Otoklav Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Otoklav Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi otoklavlar\u0131n en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Boyler Tank\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Boyler Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>TS EN ISO 4126-1 A\u015f\u0131r\u0131 Bas\u0131nca Kar\u015f\u0131 Koruma \u0130\u00e7in Emniyet Cihazlar\u0131 B\u00f6l\u00fcm 1: Emniyet Vanalar\u0131<br \/>Bu kapsamda kontrolleri ger\u00e7ekle\u015ftirilen ekipmanlar a\u015fa\u011f\u0131daki \u015fekildedir:<br \/>Hidrofor Tanklar\u0131<br \/>Genle\u015fme Tanklar\u0131<br \/>Boyler<br \/>Boyama Kazanlar\u0131<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Kaplar<br \/>Boyler Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Sorumlu personel e\u011fitim varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, kapasite ve uyar\u0131 levhalar\u0131 varl\u0131\u011f\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Bas\u0131n\u00e7l\u0131 tank\u0131n bulundu\u011fu b\u00f6lme, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri, varsa pompa ve ka\u00e7ak durumu, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7l\u0131 Tank Kontrolleri:<\/strong>\u00a0Tank deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, vana ve tesisat ba\u011flant\u0131lar\u0131, \u00f6l\u00e7\u00fc aletleri, kontrol cihazlar\u0131 ve emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar; Bas\u0131n\u00e7l\u0131 tank, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Bas\u0131n\u00e7l\u0131 tanka, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank manometresi ile test manometresi kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Boyler Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Globa\u015f m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Boyler Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 tanklar\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Kazan Dairesi Ve Is\u0131 Merkezleri Uygunluk Kontrol\u00fc<\/strong><\/summary>\n\n<p>Kazan Dairesi ve Is\u0131 Merkezleri Uygunluk Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<br \/>Yap\u0131 \u0130\u015fleri \u0130n\u015faat, Makine ve Elektrik Tesisat\u0131 Genel Teknik \u015eartnamelerine Dair Tebli\u011f<br \/>TS 2192 Kalorifer Tesisat\u0131 Yerle\u015ftirme Kurallar\u0131<br \/>TS 3818 Is\u0131tma Sistemleri-Gazl\u0131 Merkezi Yakma Tesislerinin Tasar\u0131m\u0131, Yerle\u015ftirilmesi ve G\u00fcvenlik Kurallar\u0131<br \/>TS 7363 Do\u011falgaz-Bina \u0130\u00e7 Tesisat\u0131 Projelendirme ve Uygulama Kurallar\u0131<br \/>Kazan Dairesi ve Is\u0131 Merkezleri Uygunluk Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kazanc\u0131 belgeli personel varl\u0131\u011f\u0131, kazan dairesinin sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131 ve uyar\u0131 levhalar\u0131, kapasite bilgileri, onayl\u0131 proje varl\u0131\u011f\u0131, topraklama raporu kontrol edilir.<br \/><strong>Kazan Dairesi ve Kazan Kontrolleri:<\/strong>\u00a0Kazan dairesi yerinin uygunlu\u011fu (kazan\u0131n i\u015fletme s\u0131n\u0131f\u0131 tespiti yap\u0131l\u0131r.), kazan dairesinin yang\u0131na dayan\u0131kl\u0131l\u0131\u011f\u0131, kap\u0131 uygunlu\u011fu, at\u0131k su tahliyesi, havaland\u0131rma, elektrik tesisat\u0131 ve ayd\u0131nlatma, deprem sens\u00f6r\u00fc ve kesicisi (gazl\u0131 sistemlerde), yak\u0131t deposu ve yerle\u015fimi, cihaz yerle\u015fimi, cihaz \u00e7evresinde yan\u0131c\u0131 patlay\u0131c\u0131 vb. madde varl\u0131\u011f\u0131, duman bacas\u0131, yang\u0131n s\u00f6nd\u00fcr\u00fcc\u00fcler, gerekliyse yang\u0131n dolab\u0131, solenoid vana kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>Gaz alarm\u0131; \u00c7al\u0131\u015fmas\u0131, Ex-Proof, Ses, I\u015f\u0131k, Gaz Kesme Sistemi test edilir. Kazan dairesi d\u0131\u015f\u0131ndaki \u015falterin \u00e7al\u0131\u015fmas\u0131 (gazl\u0131 sistemlerde) test edilir. Mekanik havaland\u0131rma; taze hava fan\u0131 durunca br\u00fcl\u00f6r\u00fcn durmas\u0131 test edilir. Yang\u0131n \u00f6nlemleri; acil ayd\u0131nlatma, duman alg\u0131lama, i\u015faretlemeler test edilir.<br \/>Kazan Dairesi ve Is\u0131 Merkezleri Uygunluk Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Kazan Dairesi ve Is\u0131 Merkezleri Uygunluk Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>Periyodik muayeneler kapsam\u0131nda de\u011fildir. Ekipmanlarda ve binada \u00f6nemli de\u011fi\u015fiklikler olmad\u0131\u011f\u0131 s\u00fcrece ge\u00e7erlidir.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Hava Tank\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Hava Tank\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>Hava Tank\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kompres\u00f6rden sorumlu personelin e\u011fitim belgesi varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131 kontrol edilir.<br \/><strong>Kompres\u00f6r ve Ortam Kontrolleri:<\/strong>\u00a0Kompres\u00f6r ve hava tank\u0131 b\u00f6lmesi yeri ve yerle\u015fimi, elektrik tesisat\u0131 ve ayd\u0131nlatma, hava beslemesi, kompres\u00f6r ya\u011f\u0131 durumu, kompres\u00f6r yerle\u015fimi, presostat bas\u0131n\u00e7 de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Hava Tank\u0131 Kontrolleri:<\/strong>\u00a0Tank genel durumu, kaynak diki\u015fleri uygunlu\u011fu, vanalar, emniyet ventili, manometre kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar: Hava tank\u0131, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Hava tank\u0131 tasar\u0131m bas\u0131n\u00e7 de\u011ferini a\u015fmamak \u00fczere belirlenen i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n 1,5 kat\u0131nda test bas\u0131nc\u0131 uygulan\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yap\u0131l\u0131rken kalibrasyonlu manometrelerden bas\u0131n\u00e7 takibi yap\u0131lmal\u0131d\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yava\u015f yap\u0131lmal\u0131d\u0131r. Hava tank\u0131, test bas\u0131nc\u0131nda 15 dakikadan az olmamak kayd\u0131 ile bekletilir. Bu s\u00fcre i\u00e7inde hava tank\u0131nda bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda ka\u00e7aklar\u0131n yerleri tespit edilmelidir. Emniyet ventilleri i\u015fletme taraf\u0131ndan belirlenen \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n ve\/veya hava tank\u0131 tasar\u0131m bas\u0131nc\u0131n\u0131n 1,1 kat\u0131nda a\u00e7\u0131lmal\u0131. Hava tank\u0131 i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Hava Tank\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Hava Tank\u0131 Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 hava tanklar\u0131n\u0131n en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Hi\u0307drofor Periyodik Kontrol<\/strong><\/summary>\n\n<p>Hidrofor Tank\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>TS EN ISO 4126-1 A\u015f\u0131r\u0131 Bas\u0131nca Kar\u015f\u0131 Koruma \u0130\u00e7in Emniyet Cihazlar\u0131 B\u00f6l\u00fcm 1: Emniyet Vanalar\u0131<br \/>Bu kapsamda kontrolleri ger\u00e7ekle\u015ftirilen ekipmanlar a\u015fa\u011f\u0131daki \u015fekildedir:<br \/>Hidrofor Tanklar\u0131<br \/>Genle\u015fme Tanklar\u0131<br \/>Boyler<br \/>Boyama Kazanlar\u0131<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Kaplar<br \/>Hidrofor Tank\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Sorumlu personel e\u011fitim varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, kapasite ve uyar\u0131 levhalar\u0131 varl\u0131\u011f\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Bas\u0131n\u00e7l\u0131 tank\u0131n bulundu\u011fu b\u00f6lme, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri, varsa pompa ve ka\u00e7ak durumu, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7l\u0131 Tank Kontrolleri:<\/strong>\u00a0Tank deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, vana ve tesisat ba\u011flant\u0131lar\u0131, \u00f6l\u00e7\u00fc aletleri, kontrol cihazlar\u0131 ve emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar; Bas\u0131n\u00e7l\u0131 tank, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Bas\u0131n\u00e7l\u0131 tanka, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank manometresi ile test manometresi kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Hidrofor Tank\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Hidrofor Tank\u0131 Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 tanklar\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Genle\u015fme Tank\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Genle\u015fme Tank\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>TS EN ISO 4126-1 A\u015f\u0131r\u0131 Bas\u0131nca Kar\u015f\u0131 Koruma \u0130\u00e7in Emniyet Cihazlar\u0131 B\u00f6l\u00fcm 1: Emniyet Vanalar\u0131<br \/>Bu kapsamda kontrolleri ger\u00e7ekle\u015ftirilen ekipmanlar a\u015fa\u011f\u0131daki \u015fekildedir:<br \/>Hidrofor Tanklar\u0131<br \/>Genle\u015fme Tanklar\u0131<br \/>Boyler<br \/>Boyama Kazanlar\u0131<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Kaplar<br \/>Genle\u015fme Tank\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Sorumlu personel e\u011fitim varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, kapasite ve uyar\u0131 levhalar\u0131 varl\u0131\u011f\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Bas\u0131n\u00e7l\u0131 tank\u0131n bulundu\u011fu b\u00f6lme, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri, varsa pompa ve ka\u00e7ak durumu, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7l\u0131 Tank Kontrolleri:<\/strong>\u00a0Tank deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, vana ve tesisat ba\u011flant\u0131lar\u0131, \u00f6l\u00e7\u00fc aletleri, kontrol cihazlar\u0131 ve emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar; Bas\u0131n\u00e7l\u0131 tank, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Bas\u0131n\u00e7l\u0131 tanka, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank manometresi ile test manometresi kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Genle\u015fme Tank\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Genle\u015fme Tank\u0131 Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 tanklar\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Kompres\u00f6r Hava Tank\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>TS EN ISO 4126-1 A\u015f\u0131r\u0131 Bas\u0131nca Kar\u015f\u0131 Koruma \u0130\u00e7in Emniyet Cihazlar\u0131 B\u00f6l\u00fcm 1: Emniyet Vanalar\u0131<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Sorumlu personel e\u011fitim varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, kapasite ve uyar\u0131 levhalar\u0131 varl\u0131\u011f\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Bas\u0131n\u00e7l\u0131 tank\u0131n bulundu\u011fu b\u00f6lme, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri, varsa pompa ve ka\u00e7ak durumu, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7l\u0131 Tank Kontrolleri:<\/strong>\u00a0Tank deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, vana ve tesisat ba\u011flant\u0131lar\u0131, \u00f6l\u00e7\u00fc aletleri, kontrol cihazlar\u0131 ve emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar; Bas\u0131n\u00e7l\u0131 tank, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Bas\u0131n\u00e7l\u0131 tanka, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank manometresi ile test manometresi kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 AND m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 tanklar\u0131n; en ge\u00e7 y\u0131lda bir periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Buharl\u0131 Pi\u015firme Kazan\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Buharl\u0131 Pi\u015firme Kazan\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 11673 Tencereler Yemek Pi\u015firmek \u0130\u00e7in- Sanayi Tipi (Paslanmaz)<br \/>Buharl\u0131 Pi\u015firme Kazan\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kazandan sorumlu personelin e\u011fitiminin varl\u0131\u011f\u0131, kazan sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131 ve fonksiyonlara ili\u015fkin i\u015faretlemeler kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Ortam uygunlu\u011fu, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri kontrol edilir.<br \/><strong>Pi\u015firme Kazan\u0131 Kontrolleri:<\/strong>\u00a0Kazan yerle\u015fimi, muhafazalar, yal\u0131t\u0131m durumu, \u0131s\u0131 ve buhar kayna\u011f\u0131, deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, h\u00fccre ve ceket durumu, doldurma ve bo\u015faltma vanalar\u0131, ba\u011flant\u0131lar\u0131 kontrol edilir.<br \/><strong>Fonksiyon Kontrolleri:<\/strong>\u00a0Su besleme ve tahliyesi, kapak, \u00f6l\u00e7\u00fc aletleri, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131, kontrol cihazlar\u0131, alarm cihazlar\u0131, emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar: Pi\u015firme Kazan\u0131, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Pi\u015firme Kazan\u0131na, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri pi\u015firme kazan\u0131n\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Buharl\u0131 Pi\u015firme Kazan\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Buharl\u0131 Pi\u015firme Kazan\u0131 Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 kaplar\u0131n en ge\u00e7 y\u0131lda periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Buhar Kazan\u0131 Periyodik Kontrol<\/strong><\/summary>\n\n<p>Buhar Kazan\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 2025 Buhar Kazanlar\u0131 \u0130\u015fletme, Muayene ve Bak\u0131m Genel Kurallar\u0131<br \/>Buhar Kazan\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kazan operat\u00f6r\u00fcn\u00fcn kazanc\u0131 belgesi varl\u0131\u011f\u0131, kazan sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131, vana ve hatlar\u0131 \u00fczerinde i\u015faretlemeler kontrol edilir.<br \/><strong>Kazan Dairesi, Yak\u0131t Deposu Kontrol\u00fc:<\/strong>\u00a0Kazan dairesi yeri ve yerle\u015fimi, elektrik tesisat\u0131 ve ayd\u0131nlatma kontrol\u00fc, havaland\u0131rmalar, su giderleri, gaz alarm\u0131, yang\u0131n \u00f6nlemleri, yak\u0131t tank\u0131 ve deposu kontrol edilir.<br \/><strong>Kazan Kontrolleri:<\/strong>\u00a0Kazan yerle\u015fimi, baca, su beslemesi, su seviye g\u00f6stergeleri, s\u0131v\u0131 ve gaz yak\u0131tl\u0131 kazanlarda patlama kapa\u011f\u0131, bl\u00f6fler, vanalar, presostatlar, manometre, bas\u0131n\u00e7 ve seviye alarm\u0131, emniyet ventilleri kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar: Kazan so\u011fuk olmal\u0131d\u0131r (en fazla 40-50 oC). Kazan \u0131s\u0131tma y\u00fczeyleri temiz olmal\u0131d\u0131r. Kazan ba\u011flant\u0131lar\u0131 (emniyet ventili, kazan \u00e7\u0131k\u0131\u015f\u0131 vb.) k\u00f6rlenmi\u015f olmal\u0131d\u0131r. \u0130\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Kazan\u0131n tasar\u0131m bas\u0131n\u00e7 de\u011ferini a\u015fmamak \u00fczere belirlenen i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n 1,5 kat\u0131nda test bas\u0131nc\u0131 uygulan\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yap\u0131l\u0131rken kalibrasyonlu manometrelerden bas\u0131n\u00e7 takibi yap\u0131lmal\u0131d\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yava\u015f yap\u0131lmal\u0131d\u0131r. Kazana hidrostatik deney uygulan\u0131rken, seviye g\u00f6sterge kapatma vanalar\u0131 tam kapat\u0131lm\u0131\u015f ve seviye g\u00f6sterge camlar\u0131n\u0131n bl\u00f6f\u00fc a\u00e7\u0131lm\u0131\u015f olmal\u0131d\u0131r. Kazan test bas\u0131nc\u0131nda, 30 dakikadan az olmamak kayd\u0131 ile bekletilir. Emniyet ventilleri i\u015fletme taraf\u0131ndan belirlenen \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n ve\/veya kazan tasar\u0131m bas\u0131nc\u0131n\u0131n 1,1 kat\u0131nda a\u00e7\u0131lmal\u0131. Kazan i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Buhar Kazan\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Buhar Kazan\u0131 Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi buhar kazanlar\u0131n\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>S\u0131cak Su (Kalorifer) \/ K\u0131zg\u0131n Su Kazan\u0131 Periyodik Kontrolleri<\/strong><\/summary>\n\n<p>S\u0131cak Su (Kalorifer) \/ K\u0131zg\u0131n Su Kazan\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS EN 303-1-2000 Kazanlar-\u00c7eki\u015f Br\u00fcl\u00f6rl\u00fc Kazanlar B\u00f6l\u00fcm 1: Terim ve Tarifler, Genel \u00d6zellikler, Deneyler ve \u0130\u015faretlemeler<br \/>S\u0131cak Su (Kalorifer) \/ K\u0131zg\u0131n Su Kazan\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kazan operat\u00f6r\u00fcn\u00fcn kazanc\u0131 belgesi varl\u0131\u011f\u0131, kazan sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131, vana ve hatlar\u0131 \u00fczerindeki i\u015faretlemeler kontrol edilmelidir.<br \/><strong>Kazan Dairesi ve Yak\u0131t Deposu Kontrol\u00fc:<\/strong>\u00a0Kazan dairesi yeri ve yerle\u015fimi, elektrik tesisat\u0131 ve ayd\u0131nlatma, havaland\u0131rmalar, su gideri, gaz alarm\u0131, yang\u0131n \u00f6nlemleri, yak\u0131t tank\u0131\/deposu kontrol edilir.<br \/><strong>Kazan Kontrolleri:<\/strong>\u00a0Kazan yerle\u015fimi, baca, su beslemesi, s\u0131v\u0131 ve gaz yak\u0131tl\u0131 kazanlarda patlama kapa\u011f\u0131, vanalar, termostat, manometre, genle\u015fme tank\u0131 ve ba\u011flant\u0131s\u0131, emniyet ventilleri kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar: Kazan so\u011fuk olmal\u0131d\u0131r (en fazla 40-50 oC). Kazan \u0131s\u0131tma y\u00fczeyleri temiz olmal\u0131d\u0131r. Kazan ba\u011flant\u0131lar\u0131 (emniyet ventili, kazan \u00e7\u0131k\u0131\u015f\u0131 vb.) k\u00f6rlenmi\u015f olmal\u0131d\u0131r. \u0130\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Kazan\u0131n tasar\u0131m bas\u0131n\u00e7 de\u011ferini a\u015fmamak \u00fczere belirlenen i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n 1,5 kat\u0131nda test bas\u0131nc\u0131 uygulan\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yap\u0131l\u0131rken kalibrasyonlu manometrelerden bas\u0131n\u00e7 takibi yap\u0131lmal\u0131d\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yava\u015f yap\u0131lmal\u0131d\u0131r. Kazana hidrostatik deney uygulan\u0131rken, seviye g\u00f6sterge kapatma vanalar\u0131 tam kapat\u0131lm\u0131\u015f ve seviye g\u00f6sterge camlar\u0131n\u0131n bl\u00f6f\u00fc a\u00e7\u0131lm\u0131\u015f olmal\u0131d\u0131r. Kazan test bas\u0131nc\u0131nda, 30 dakikadan az olmamak kayd\u0131 ile bekletilir. Emniyet ventilleri i\u015fletme taraf\u0131ndan belirlenen \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n ve\/veya kazan tasar\u0131m bas\u0131nc\u0131n\u0131n 1,1 kat\u0131nda a\u00e7\u0131lmal\u0131. Kazan i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>S\u0131cak Su (Kalorifer) \/ K\u0131zg\u0131n Su Kazan\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>S\u0131cak Su (Kalorifer) \/ K\u0131zg\u0131n Su Kazan\u0131 Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi s\u0131cak su ve k\u0131zg\u0131n su kazanlar\u0131n\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrol<\/strong><\/summary>\n\n<p>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS 1203 EN 286-1 Tanklar-Basit Alev Almayan Bas\u0131n\u00e7l\u0131 Hava veya Azot Depolamak \u0130\u00e7in Tasarlanm\u0131\u015f- B\u00f6l\u00fcm 1: Genel Ama\u00e7lar \u0130\u00e7in Bas\u0131n\u00e7l\u0131 Tanklar<br \/>TS EN 13445-5 Bas\u0131n\u00e7l\u0131 Kaplar-Ate\u015fle Temas Etmeyen- B\u00f6l\u00fcm 5: Muayene ve Deney Standard\u0131<br \/>TS EN ISO 4126-1 A\u015f\u0131r\u0131 Bas\u0131nca Kar\u015f\u0131 Koruma \u0130\u00e7in Emniyet Cihazlar\u0131 B\u00f6l\u00fcm 1: Emniyet Vanalar\u0131<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Sorumlu personel e\u011fitim varl\u0131\u011f\u0131, ekipman\u0131n sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, kapasite ve uyar\u0131 levhalar\u0131 varl\u0131\u011f\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7 Kayna\u011f\u0131 ve Ortam Kontrolleri:<\/strong>\u00a0Bas\u0131n\u00e7l\u0131 tank\u0131n bulundu\u011fu b\u00f6lme, elektrik tesisat\u0131 ve ayd\u0131nlatma, su gideri ve yer s\u00fczge\u00e7leri, varsa pompa ve ka\u00e7ak durumu, presostat ayar de\u011ferleri ve \u00e7al\u0131\u015fmas\u0131 kontrol edilir.<br \/><strong>Bas\u0131n\u00e7l\u0131 Tank Kontrolleri:<\/strong>\u00a0Tank deformasyon ve korozyon durumu, kaynak diki\u015fleri uygunlu\u011fu, vana ve tesisat ba\u011flant\u0131lar\u0131, \u00f6l\u00e7\u00fc aletleri, kontrol cihazlar\u0131 ve emniyet ventili kontrol edilir.<br \/><strong>Testler:<\/strong>\u00a0\u00d6n haz\u0131rl\u0131klar; Bas\u0131n\u00e7l\u0131 tank, i\u00e7inde hava kalmayacak \u015fekilde suyla doldurulmu\u015f olmal\u0131d\u0131r. Ba\u011flant\u0131lar ve emniyet ventili k\u00f6rlenmi\u015f olmal\u0131d\u0131r. Bas\u0131n\u00e7l\u0131 tanka, etikette belirtilen tasar\u0131m bas\u0131nc\u0131 de\u011ferini a\u015fmamak \u00fczere belirlenen, i\u015fletme bas\u0131nc\u0131n\u0131n 1,5 kat\u0131na kadar bas\u0131n\u00e7 uygulan\u0131r. Bas\u0131n\u00e7 yava\u015f yava\u015f ve tankta g\u00f6zlem yap\u0131larak uygulan\u0131r. Bas\u0131n\u00e7l\u0131 tank manometresi ile test manometresi kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. Bas\u0131n\u00e7l\u0131 tank test bas\u0131nc\u0131nda, en az 30 dakika olmak \u00fczere, incelemeye yeterli olacak s\u00fcre kadar tutulur. Bu s\u00fcre i\u00e7inde bas\u0131n\u00e7 d\u00fc\u015fmesi olmas\u0131 durumunda m\u00fcmk\u00fcnse ka\u00e7aklar\u0131n yerleri tespit edilir. Emniyet ventilleri bas\u0131n\u00e7l\u0131 tank\u0131n en y\u00fcksek \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 1,1 kat\u0131na gelmeden tam kapasitede a\u00e7\u0131lmal\u0131 ve bas\u0131n\u00e7l\u0131 tank i\u015fletme bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>Genel Ama\u00e7l\u0131 Bas\u0131n\u00e7l\u0131 Tanklar Periyodik Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi bas\u0131n\u00e7l\u0131 tanklar\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details><hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\" \/><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\">\n<summary><strong>K\u0131zg\u0131n Ya\u011f Kazan\u0131 Periyodik Kontrolleri<\/strong><br \/><br \/><br \/><\/summary>\n\n<p>K\u0131zg\u0131n Ya\u011f Kazan\u0131 Periyodik Kontrolleri Hangi Standarda G\u00f6re Yap\u0131lmaktad\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi<br \/>TS EN 303-1-2000 Kazanlar-Cebri \u00c7eki\u015f Br\u00fcl\u00f6rl\u00fc Kazanlar B\u00f6l\u00fcm 1: Terim ve Tarifler, Genel \u00d6zellikler, Deneyler ve \u0130\u015faretleme<br \/>K\u0131zg\u0131n Ya\u011f Kazan\u0131 Periyodik Kontrolleri Nas\u0131l Yap\u0131l\u0131r?<br \/><strong>Genel Kontroller:<\/strong>\u00a0Kazan operat\u00f6r\u00fcn\u00fcn kazanc\u0131 belgesi varl\u0131\u011f\u0131, kazan sicil kart\u0131, bak\u0131m onar\u0131m kay\u0131tlar\u0131, kullanma talimatlar\u0131, uyar\u0131 ve kapasite levhalar\u0131, vana ve hatlar\u0131 \u00fczerindeki i\u015faretlemeler kontrol edilir.<br \/><strong>Kazan Dairesi ve Yak\u0131t Deposu Kontrol\u00fc:<\/strong>\u00a0Kazan dairesi yeri ve yerle\u015fimi, elektrik tesisat\u0131 ve ayd\u0131nlatma, havaland\u0131rmalar, su gideri ve ya\u011f at\u0131klar\u0131, gaz alarm\u0131, yang\u0131n \u00f6nlemleri, yak\u0131t tank\u0131\/deposu kontrol edilir.<br \/><strong>Kazan Kontrolleri:<\/strong>\u00a0Kazan yerle\u015fimi, baca, sirk\u00fclasyon pompalar\u0131 durumu, ya\u011f besleme sistemi, s\u0131v\u0131 ve gaz yak\u0131tl\u0131 kazanlarda patlama kapa\u011f\u0131, vanalar, termostat, ak\u0131\u015f kontrol cihazlar\u0131, manometre, genle\u015fme tank\u0131 ve ba\u011flant\u0131s\u0131, emniyet ventilleri kontrol edilir.<br \/><strong>Testler:<\/strong><br \/>\u00d6n haz\u0131rl\u0131klar: Kazan so\u011fuk olmal\u0131d\u0131r (en fazla 40-50 oC). Kazan \u0131s\u0131tma y\u00fczeyleri temiz olmal\u0131d\u0131r. Kazan ba\u011flant\u0131lar\u0131 (emniyet ventili, kazan \u00e7\u0131k\u0131\u015f\u0131 vb.) k\u00f6rlenmi\u015f olmal\u0131d\u0131r. \u0130\u00e7inde hava kalmayacak \u015fekilde ya\u011fla doldurulmu\u015f olmal\u0131d\u0131r. Kazana, kazanda kullan\u0131lan ya\u011fla bas\u0131n\u00e7 uygulan\u0131r. Kazan\u0131n tasar\u0131m bas\u0131n\u00e7 de\u011ferini a\u015fmamak \u00fczere belirlenen i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n 1,5 kat\u0131nda test bas\u0131nc\u0131 uygulan\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yap\u0131l\u0131rken kalibrasyonlu manometrelerden bas\u0131n\u00e7 takibi yap\u0131lmal\u0131d\u0131r. Bas\u0131n\u00e7land\u0131rma i\u015flemi yava\u015f yap\u0131lmal\u0131d\u0131r. Kazana hidrostatik deney uygulan\u0131rken, seviye g\u00f6sterge kapatma vanalar\u0131 tam kapat\u0131lm\u0131\u015f ve seviye g\u00f6sterge camlar\u0131n\u0131n bl\u00f6f\u00fc a\u00e7\u0131lm\u0131\u015f olmal\u0131d\u0131r. Kazan test bas\u0131nc\u0131nda, 30 dakikadan az olmamak kayd\u0131 ile bekletilir. Emniyet ventilleri i\u015fletme taraf\u0131ndan belirlenen \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n ve\/veya kazan tasar\u0131m bas\u0131nc\u0131n\u0131n 1,1 kat\u0131nda a\u00e7\u0131lmal\u0131. Kazan i\u015fletme bas\u0131nc\u0131n\u0131n ve\/veya tasar\u0131m bas\u0131nc\u0131n\u0131n alt\u0131na d\u00fc\u015ft\u00fckten sonra kapanmal\u0131d\u0131r.<br \/>K\u0131zg\u0131n Ya\u011f Kazan\u0131 Periyodik Kontrolleri Kim Taraf\u0131ndan Yap\u0131l\u0131r?<br \/>Standartlarda belirtilen kriterlere uygun olarak uzman ve sertifikal\u0131 Sigmacert Global m\u00fchendisleri taraf\u0131ndan yap\u0131l\u0131r.<br \/>K\u0131zg\u0131n Ya\u011f Kazan\u0131 Kontrolleri Hangi S\u0131kl\u0131kla Yap\u0131l\u0131r?<br \/>\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi gere\u011fi k\u0131zg\u0131n ya\u011f kazanlar\u0131n\u0131n; en ge\u00e7 y\u0131lda 1 periyodik olarak ve gerekti\u011finde kontrol ve deneyleri yapt\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<\/details>\n<p>\u00a0<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Bas\u0131n\u00e7l\u0131 Kaplar \u00a0<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-104","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/pages\/104","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=104"}],"version-history":[{"count":27,"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/pages\/104\/revisions"}],"predecessor-version":[{"id":476,"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=\/wp\/v2\/pages\/104\/revisions\/476"}],"wp:attachment":[{"href":"https:\/\/sigmacertteknik.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}